Uzin PE 460 2 part Moisture Barrier 100% RH 10kg kit
$60.7
$103.19
More about the product Main application field – Barrier primer on unheated cementitious screeds or on concrete up to 98 % R. H.** (5 CM-%) – Barrier primer on heated constructions up to 90 % R. H.** (3 CM-%) – Hardener for weak, porous or cracked substrates – Bonding primer prior to installation with UZIN levelling compounds Suitable on/for – Dense or absorbent existing substrates – Cement or gypsum screeds, magnesia or xylolite screeds, concrete, P4 – P7 and OSB 2 – OSB 4 boards or precast screeds – On existing or ungritted mastic asphalt – Ceramic or natural stone floors, terrazzo, metal (contact UZIN Technical Service for advise), matt-sanded coatings and sealants – Gritbinded or in connection with UZIN PE 280 prior to in stallation with UZIN cement or calcium sulphate levelling compounds – Exposure to castor wheels in accordance with DIN EN 12 529 – Suitable for residential, commercial and industrial areas Extended applications – EP levelling compound when mixed with UZIN Perlsand 0.8 or quartz powder mix – EP mortar when mixed with special filler UZIN XS 3.2, strength class SR-C35-F10 according to DIN EN 13 813 – Primer prior to bonding work with epoxy-, PUR- or silane-based adhesives Substrate preparation The substrate must be sound, load-bearing, dry, free from cracks and free from materials (dirt, oil, grease) that would impair adhesion. Test the substrate in accordance with ap plicable standard or notices and report any deficiencies. Any adhesion-reducing or unstable layers, e.g. release agents, loose adhesives, compounds, covering or paint residues, etc. must be removed, e.g. by brushing, abrading, grinding or shot-blasting. Dense, smooth and metal sur faces should be degreased and abraded. On metal, pre-test for adhesion strength. Allow the primer to dry completely. The datasheets for other used products have to be ob served. Application 1. Before use, allow the combi-cans to come to room temperature. Punch several times through the plastic plug and the floor of the upper container (hardener B). Allow the hardener to drain completely into the lower container (resin A). Remove the empty upper container and thoroughly blend the components with a spiral mixer (A). De cant the mixed material into an oval bucket and mix once again. 2. Immediately apply an even coat of the primer onto the substrate with the UZIN Nylon Fibre Roller (B). On smooth surfaces, it can be spread with a B2 notched trowel and then evenly rolled out. Ensure a fully sealed coat. Pay attention to the limited working time. 3. When the coat is dry to accept foot traffic, but within 48 hours, apply the second coat crosswise. For a visual differentiation between the coats, mix approx. 4. With subsequent application of levelling compounds, the last wet coat has to be gritbinded immediately with UZIN Quartz Sand 0.8 (approx. 3 kg/m²). After curing vacuum thoroughly. 5. In case of using UZIN PE 460 as a moisture barrier and using UZIN PE 280 as a bonding primer on top, the mini mum quantity of UZIN PE 460 has to be 500 g/m² in one layer. 6. Clean tools immediately after use considering the recommended safety measures. Hardened material can only be removed mechanically. When applying the material always wear the recommended safety equipment. Important notes A shelf life of 12 months when stored in moderately cool conditions, in the original packaging. Allow containers to come to room temperature before use. Best applied between 15 – 20 °C, with the floor temperature above 15 °C and relative air humidity below 65%. High temperatures and high air humidity shorten the drying time. Whilst low temperatures and low air humidity lengthen the drying time. Caution: Epoxy material can become extremely hot after mixing in the container. Therefore use the material immediately, don’t leave the container unattended after mixing and take the bucket outside after use to allow residues to cure. Two coats are required when using as a moisture barrier up to 98 % R. H.** (5 CM-%). A surface barrier cannot be applied onto old cement screeds with levelling compound residues or moisture sensitive substrates. Contact UZIN Technical Service for advice if a moisture barrier is required on cementitious screeds with under floor heating or concrete sole plates are present. When used over underfloor heating ensure it has been commissioned and fully tested in accordance with the manufactures guidelines. If installing wooden floors with UZIN reactive resin adhesives directly to the primer this must happen within 48 hours after applying the primer. For use in PAH decontamination please refer to the de tailed system recommendations and notes on the internet (www.uzin.com). For use as a levelling compound, allow the primer to dry. Apply the compound within 24 to 36 hours on the cured primer. If this is not possible, blind the wet primer with UZIN Perlsand 0.8. Once cured, remove any loose sand which has not embedded. Apply epoxy mortar “wet in wet” on the primer. When used as a screed in interior areas and a layer thickness > 10 mm, proof of fire must be provided by the manufacturer of the screed mortar. Protect freshly applied epoxy mortar areas from draughts, direct sunlight and sources of heat. Do not mix partial quantities! When mixed with the UZIN Epoxy Accelerator it will not achieve EC 1 PLUS classification. Follow the generally acknowledged rules of the trade and technology for the installation of wood flooring and floor covering in respective of the applicable national standards (e.g. EN, DIN, OE, SIA, etc.). Seals of quality & ecolabels – Solvent-free – EMICODE EC 1 PLUS / Very low emission Composition Polyamine-hardened epoxy resin. Protection of the workplace and the environment Solvent-free. Non flammable. Comp. A: Contains epoxy resin/irritant. Comp. B: Contains amine hardener/corrosive. Both components: May cause irritations or burns to eyes, skin or respiratory system. May cause sensitisation by skin contact. After contact with skin, wash immediately withplenty of water and soap. In case of contact with eyes, rinse im mediately with plenty of water and seek medical advice. Use barrier cream, protective gloves and safety-goggles. In liquid form, ”hazardous to the environment”, therefore do not allow into drains, water courses or landfill. Observe safety information on product label as well as safety data sheet. Once cured, has neutral odour and presents no physiological or ecological risk. Disposal Where possible, collect product residues and re-use. Do not allow dispersal into drains, sewers or ground. Empty, scraped and drip-free containers are recyclable. Containers with liquid residue, as well as the liquid product, are classed as Special Waste. Dried product residues are classed as Construction Waste. Therefore collect waste material, mix both components and allow to harden, then dispose as Construction Waste.
Moisture Barriers & Primers